Manufacturer and distributor of liquid handling systems.

 

 
        

Solution Values by TVA


 
Product S.G. % H20 Lbs. /Gal Gal/Ton S.O. Temp.
28-0-0 1.28 30.20 10.68 187.27 -1
30-0-0 1.30 25.20 10.84 184.50 14
32-0-0 1.32 20.02 11.01 181.65 28
8-24-0 1.29 53.80 10.76 185.90 20
10-34-0 1.41 37.00 11.76 170.07 -10
11-37-0 1.44 32.00 12.01 166.53 25
12-0-0-26 1.337 39.50 11.15 179.37 25
3-9-9 1.22 67.00 10.17 196.66 0
4-10-10 1.23 61.00 10.26 194.93 25
4-11-11 1.26 59.00 10.51 190.29 46
0-0-62 1.17 00.00 9.76 184.43  
10-0-0-10zn 1.27 63.00 10.59 188.86 32
 

The gallons/ton for 0-0-62 is calculated as follows:

SG of 0-0-62 x 8.34 divided into 2000 x 0.9

 

Viscosity of UAN solutions


Temp 28-0-0 30-0-0 32-0-0 10-34-0
(F) (cp) (cp) (cp) (cp)
20 41 45 ** 165
40 36 40 48 138
60 31 37 44 110
80 26 31 37 83
100 21 26 32 55
S.O. Temp 1 15 32 -10
 
** Crystal present
 

These values have been checked for accuracy.  

If they differ from yours, you should use those you like.

 
 
 
Last Updated: 12/21/2006

(C)2005 Murray Equipment, Inc.

Murray Equipment, Inc. 2515 Charleston Place Fort Wayne, Indiana 46808

Toll Free: (800) 348-4753 or (260) 484-0382     Fax:(260) 484-9230