Durant Preset Operating Procedures


Normal Operation

  1. Reset counter by pressing Reset key.
  2. To run without changing preset value, go to step 7.
  3. Press Preset.
  4. Enter desired amount via keypad.
  5. Press Enter.
  6. Press Count.
  7. Press Start button.

Entering a Preset Value

  1. Press the Preset button.  [1] The preset will display the current value.  If the value is the same as the desired value, go to step 4.
  2. Enter the desired value via the keypad.
  3. Press the Enter key.
  4. Press the Count key to return to normal operation.
 
Example:  To change the preset value to 10, press:
Preset, 1, 0, Enter, Count

Set-up Procedure

  1. Turn to page 19 in the installation and operation manual.  The correct values for each relevant programming function codes should be circled.  If the function code values are not marked, call Murray Equipment for the correct values or refer to the following chart.
 

Model 58821-400 (Preset with Scaling)

Function Code

Value

Description
5 * Scale Factor
60 1 Count Up
30 .00 No Timeout
36 1 Latch until reset
 

Model 58820-400 (Preset without Scaling)

Function Code

Value

Description
60 1 Count Up
62 1 0000.0 decimal display
30 .00 No Timeout
36 1 Latch until reset
  

Model 58851-400 (Dual Level Preset - Pursuit)

Function Code

Value

Description
26 1 Totalizer counts in opposite direction
30 .00 No Timeout
31 .00 No Timeout
36 3 Latch until reset complete (output 1 & 2)
61 1 Totalizer operates in count mode
62 2 0000.00 decimal point display
78 1 Terminal 4 is totalizer reset
80 1 Preset mode

 

Model 58811-400 (Eight digit totalizer hoftotbox)

Function Code

Value

Description
5 * Scale Factor
60 1 Count Up

 

  1. To change a function code value, press the Function button on the face of the preset, enter the Function Code, and press Enter.
  2. Enter the desired new value for the selected function code via the keypad.  Press Enter to accept this value.
  3. Press Count to return preset to normal operation.  This procedure will need to be repeated for each function code you wish to change.
 
Example:  To change count operation mode to 1, press:
Function, 6, 0, Enter, 1, Enter, Count.
 

Calibration and Scale Factors

  1. Obtain an accurate method of measuring the calibration product.  This can be a scale or test prover of known volume.
  2. Run test product through system for at least a minute to obtain a good sample with no entrapped air.
  3. Reset the preset counter to zero, and run a test into the calibration prover.
  4. Record the count value on the preset and the actual volume in the prover into the following formula.
 

(Actual amount run ¸ Count on preset) x Existing scale factor = New scale factor.

 
  1. Enter new scale factor into preset, and run another test to confirm new calibration.  Repeat  scale factor calculation if calibration is off.

Display or Change Scale Factor

 
  1. Press the Function button, press 5, press Enter.
  2. The current scale factor will display on preset.
  3. Press Count to exit with no change or key in a new scale factor value via the keypad.
  4. Press Enter to accept new scale factor value.
  5. Press Count to return to normal operating mode.
 

 
 
 
Last Updated: 12/21/2006